THÔNG SỐ KỸ THUẬT:
ENERTRONIC I 3-3 (three-phase input and | three-phase output) | |||||||||||||
Power*1 (cosj = 0.8) | [kVA] | 10 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 140 | 160 | 200 | 240 |
Power*1 (cosj = 1.0) | [kW] | 8 | 16 | 24 | 32 | 40 | 48 | 64 | 80 | 96 | 112 | 128 | 160 | 192 |
Operating temperature range 0 … 40 °C (reduction in power beyond this) Relative air humidity 5 … 95% (non-condensing) Volume < 65 dBA (as a function of power) Protection class IP20 (further classes on request) Installation height 1000 m (without reduction in power) Cable entry point below (above on request) Colour RAL 7035 (other colours on request) Ventilation redundant forced-air ventilated Classification VFI-SS-111 (according to IEC / EN 62040-3) Standards Safety IEC / EN 62040-1, IEC / EN 60950-1 EMC IEC / EN 62040-2 Power IEC / EN 62040-3 Input Voltage 3 / N 400 V ± 15% (further voltages on request) Frequency 50 Hz ± 5% / 60 Hz ± 5% THDi (100% load) ≤ 5 Input power factor ≥ 0.99 Transformer Isolation transformer as an option Output (inverter mode) Voltage 380 V / 400 V / 415 V (further voltages on request) Voltage tolerance (static) ± 1% Frequency tolerance ± 0.1% Total harmonics distortion THDu Linear Load ≤ 1% Efficiency up to 94% (as a function of the configuration) Overload operation – inverter 200% for 3 s, 150% for 60 s, 125% for 10 min Overload operation – bypass 1000% for 100 ms, 150% for 10 min Short-circuit behaviour – inverter up to 350% for 3 s (up to 700% as an option) Short-circuit behaviour – bypass 1000% for 100 ms Transformer isolation transformer Battery Nominal voltage 110 V 220 V 400 V Battery technologies Lead, nickel cadmium, lithium Ion (optional) |
ENERTRONIC I 3-1 (three-phase input and | single-phase outp | ut) | |||||||||||
Power (cosj = 0.8) | [kVA] | 10 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 140 | 160 | 200 |
Power (cosj = 1.0) | [kW] | 8 | 16 | 24 | 32 | 40 | 48 | 64 | 80 | 96 | 112 | 128 | 160 |
Operating temperature range 0 … 40 °C (reduction in power beyond that) Relative air humidity 5 … 95% (non-condensing) Volume < 65 dBA (as a function of power) Protection class IP20 (further classes on request) Installation height 1000 m (without reduction in power) Cable entry point below (above on request) Colour RAL 7035 (other colours on request) Ventilation redundant forced-air ventilated Classification VFI-SS-111 (according to IEC / EN 62040-3) Standards Safety IEC / EN 62040-1, IEC / EN 60950-1 EMC IEC / EN 62040-2 Power IEC / EN 62040-3 Input Voltage 3 / N 400 V ±15% (further voltages on request) Frequency 50 Hz ± 5% / 60 Hz ± 5% THDi (100% load) ≤ 5 Input power factor ≥ 0.99 Transformer Isolation transformer as an option Output (inverter mode) Voltage 220 V / 230 V / 240 V (further voltages on request) Voltage tolerance (static) ± 1% Frequency tolerance ± 0.1% Total harmonics distortion THDu Linear load: < 1% Efficiency up to 91% (as a function of configuration) Overload operation – inverter 200% for 3 s, 150% for 60 s, 125% for 10 min Overload operation – bypass 500% for 100 ms, 150% for 10 min Short-circuit behaviour – inverter 300% for 3 s (up to 400% as an option) Short-circuit behaviour – bypass 500% for 100 ms Transformer Isolation transformer Battery Nominal voltage 110 V 220 V Battery technologies Lead, nickel cadmium, lithium ion (optional) |