THÔNG SỐ KỸ THUẬT:
| Model | PWR 11-1 | PWR 11-2 | PWR 11-3 | PWR 11-5 | PWR 11-6 | PWR 11-7 | PWR 11-10 | PWR 11-15 | ||||
| Power (kVA) | 1 | 2 | 3 | 5 | 6 | 7 | 10 | 15 | ||||
| Entrance | ||||||||||||
| Entrance power factor | 0.99 at THDI < %4 | |||||||||||
| Voltage and tolerance | 220 VAC Faz+N.+%20.3 / 220 VAC 3 phase + N. + 20% | |||||||||||
| By-pass toleransı/By-pass and tolerance | 220 VAC 3 phase + N. + 15% | |||||||||||
| Current | 9A | 13A | 20A | 31A | 36A | 44A | 52A | 90A | ||||
| Input Frequency | 50 Hz +/-5% | |||||||||||
| EMI | BN 50091-2 class | |||||||||||
| Input voltage protection | Electronic entrance voltage tolerance out protection | |||||||||||
| Exit | ||||||||||||
| Power (kVA) | 0.9 | 1.8 | 2.7 | 4.5 | 5.4 | 6.3 | 9 | 12 | ||||
| Power factor | 0,9 | |||||||||||
| Gerilim /Voltage | 220VAC (220/380 VAC) 1 phase + N.+ /1% 3% | |||||||||||
| frequency | 50 Hz | |||||||||||
| Frequency tolerance | Network to synchronize: + / – 2% | |||||||||||
| Efficiency | > %90 | |||||||||||
| Crest factor | 3.1 | |||||||||||
| Overload protection | 100-% 125% load: 10 minutes | |||||||||||
| At 125-% to 150% load: 1 minute | ||||||||||||
| > 150% load: static bypass | ||||||||||||
| Output voltage protection | Elektronik çıkış voltajı tolerans dışı koruması/ Electronic output voltage tolerance out protection | |||||||||||
| THD (%100 lineer yükte) / | <3% (non-linear load <5%) | |||||||||||
| THD (100% linear load) | ||||||||||||
| Battery | ||||||||||||
| Type | Maintenance-free, sealed lead | |||||||||||
| Number of Batteries | 16×20 | 20×20 | ||||||||||
| Charging voltage | 189 VDC | 189VDC | 189VDC | 216VDC | 270VDC | |||||||
| 140VDC | 140VDC | 140VDC | 160VDC | 200VDC | ||||||||
| Battery cabinet | Internal | Exterrnal | ||||||||||
| Battery operating temperature | < 25°C | |||||||||||
| Battery protection | Automatic circuit breakers | |||||||||||
| Battery volt.protection | Electronic battery out of tolerance protection | |||||||||||
| Battery test | Once a week as standard ,scheduling available | |||||||||||
| General | ||||||||||||
| Interface | 2×16 LCD display | |||||||||||
| Communication | Dry contact and RS232 | |||||||||||
| Software | RS232, RS485 (Modbus) | |||||||||||
| Protections | Over heat, overload, high and low input, output low-high protection | |||||||||||
| Storage temperature range | -15/+50 °C | |||||||||||
| Operating temperature range | 0-40 °C | |||||||||||
| Protection class | IP20 | |||||||||||
| Humidity | %0 – %90 | |||||||||||
| Maximum working height | <2000 m above sea level | |||||||||||
| Noise level (in 1m.distance) | < 45 dBA | < 50 dBA | <55 dBA | |||||||||
| Without battery weight (kg) | 50 | 55 | 60 | 75 | 91 | 112 | ||||||
| Dimensions (mm) HxWxD | 540x265x560 | 540x265x560 | 635x265x665 | |||||||||
| Options | ||||||||||||
| Output Transformers | Galvanic isolation transformer | |||||||||||
| PRC | Input power factor | |||||||||||
| MBS | Maintenance by-pass for the isolation of the UPS | |||||||||||
| Parallel Operation | 1+3 sistem / 1 + 3 system | |||||||||||
| Standarts | EN62040-1-1, EN 62040-3 EN50091-2,CE | |||||||||||